1. Characteristics
The wireless high and low voltage transformation ratio tester is also called high and low voltage<>The wireless transformation ratio tester consists of a high voltage detector, a low voltage current clamp, a host, a high voltage insulating rod, monitoring software, communication lines, etc. The instrument uses fast digital circuit processing technology to measure the following high-voltage current transformers, primary currents of transformers, high-voltage primary currents, low-voltage secondary currents, and The transformation ratio value, phase difference, polarity, and transformation ratio error can be calculated.
When the insulating rod is not used, it can also be used as a high-precision low-voltage clamp ammeter or leakage ammeter<> It is simple to use and easy to carry
. Its wireless transmission function can be received within a straight line<> meters The measured data ensures high precision, high reliability and high stability of uninterrupted testing all year round. The host adopts a large screen display and is small in size, light in weight and easy to carry. It can save data sets. High voltage current measurement range
.~<> Low voltage current measurement range
.~<>.
The current signal of the high-voltage detector uses wireless transmission technology to connect the retractable insulating rod. By pushing forward or withdrawing the insulating rod, it is convenient to clamp or evacuate the wire under test, saving time and speed. It can be widely used in substations, power plants, and industrial and mining enterprises. As well as testing stations and electrician maintenance departments for current testing and field electrical work. Insulating rods are lightweight, moisture-proof, high temperature resistant, impact resistant, bending resistant, highly insulating and retractable.
2. Technical parameters
r
r tester
High voltage detector
Host (current clamp)
rRange
~(/Auto)
~
rResolution
rClamp Mouth size
&;
&;.
rTest accuracy
&;%&;
&;<>.%&;
r sampling rate
times/second
r function
Current and transformer of primary and secondary circuits of high and low voltage current transformers Ratio, polarity, phase difference, online testing; online testing of current magnitude and transformation ratio on both sides of the transformer; load current testing
rTransmission type
Wireless transmission straight line transmission distance< >
rShifting
Fully automatic shifting
rPower supply
Small alkaline battery (. &;<>)< br/> Small alkaline battery (.&;<>)
rTest method
Clamp type
rOutline dimensions
Width, thickness and height**
Host: Width, thickness and height<>**
Current clamp: Width, thickness and height**
rDisplay mode
:<>
&;<>The blue screen backlight function is suitable for dark places
r
Size
&;<>
rTransformation ratio
One type of transformation ratio display<>: (The actual measured current transformation ratio of the primary and secondary circuits; the converted transformation ratio of the secondary circuit; the converted transformation ratio of the transformer / Ratio) Maximum transformation ratio: 10 million
r Line voltage
The following line test with an insulating sheath or the following bare conductor current test (must operate with an insulating rod)< br/>
rLead length
Current clamp lead meters
rQuality
Total mass of the instrument:.( Including insulating rod and instrument package)
High voltage detector: (including battery)
Host: (including battery)
Current clamp:
rData interface
B transmission
rOverflow display
Over-range overflow function: &; symbol display
rData storage
Group press<>
key to hold the data<>R
symbol is displayed and then press
key to cancel holding
< br/>rData review
Long press the <>
key to enter the data review mode
rData storage is full
Data storage Full function: &; symbol display
rNo signal indication
When the host does not receive the transmission signal, it prompts &;<>
rAutomatic shutdown
The meter will automatically shut down about <> minutes after powering on
rBattery voltage
When the battery voltage drops to., the low battery indicator light will light up as a reminder. Replace the battery
When the battery voltage drops to., the low battery voltage symbol displays to remind you to replace the battery
rInsulation rod
Five retractable insulating rods (meters)< br/>
rInsulation strength
/r
rLine test
Test the bare conductors below the line voltage with insulated sheathed wires Test (operating with insulating rod)
rOperating temperature
-℃~℃
rStorage temperature
- ℃~℃
rRelative humidity
℃~℃≦%℃~℃≦%
rSuitable for safety regulations
/> -,, pollution level, III () (standard)
3. Packing list
r
rHigh voltage detector
Taiwan
rHost
Taiwan
rCurrent clamp
Taiwan
< br/>rRetractable insulating rod
Set (meter)
rInstrument package
Individual
rBattery
High voltage detector: No. Alkaline dry battery section
Low-voltage host: No. Alkaline dry battery section
rData cable
Articles
rInstructions, warranty
br/> Set
Wireless digital display high voltage transformation ratio tester ES1010